Speedsleep Specifications
![]() |
![]() |
6, 9 & 12m - Full-length, full-width structurally welded steel chassis with two 175 x 50mm lipped-channel, longitudinal beams. Outriggers and crossmembers are of 75 x 38 channel.
15 & 18m - Full-length, full-width structurally welded steel chassis with two 250 x 75mm lipped-channel, longitudinal beams. Outriggers and crossmembers are of 75 x 38 channel.
The complete assembly is sand blasted and coated with self-etch red oxide primer. For added protection, the chassis is coated with a waterproof, malleable compound called Plaswax or similar which forms a tenacious wax-like surfacing.
ROOF AND CEILING CONSTRUCTION
The roof is a bow-rafter type construction of SA Pine timber. All the roof and ceiling timber is treated according to SABS 1288:1994. The roof exterior is covered with galvanised sheeting 0,5mm thick, 100 micron plastic which acts as a vapour barrier and gives added insulation above the 50mm thick, 12kg/m3 pink fibreglass wool insulation covering the top of the ceiling. Ceilings are 4,8mm thick hardboard with an embossed, washable PVC vinylast covering on the interior.
SIDEWALL CONSTRUCTION
6, 9 & 12m - The standard exterior and interior finish is 0,5mm Chromadek, which is a galvanised, prepainted (frost white) finish. The perimeter and internal walls are fully insulated with 40mm thick high-density foam. As an optional extra interior wall panels can be covered with 4mm thick decorative patterned plywood finish.
15 & 18m - The sidewalls are rigidly framed with timber treated, according to SABS 1288:1994 SA Pine timber studs at 400mm centres. The perimeter walls are fully insulated with 50mm thick, 12kg/m3 pink fibreglass wool. Interior wall panels are 4mm thick decorative patterned plywood finish. Panels are precisely fitted, glued and fastened to the studs.
The standard exterior finish is 0,5mm Chromadek, which is a galvanised, prepainted finish.
WINDOWS
All window frames are aluminium fitted with 4mm thick glass. The area of the windows is equal to or greater than 10% of the gross floor area of each habitable room.
FLOOR CONSTRUCTION
18mm Treated timber floorboards are glued and screwed to crossmembers and covered in 2mm industrial vinyl welded at joints. Carpet covering optional extra.
ELECTRICS
Units are wired for connecting to 220 volt supply in accordance with SABS 0142:1987 and are fitted with earth-leakage protection and distribution board. Lights, plugs, geyser and interior electrical fittings are installed as shown on the layout diagrams.
PLUMBING
Copper, stainless steel, or Polycop piping is used for water supply and PVC fittings for sewerage and wastewater.
TRANSPORT AND HANDLING
It is extremely important that the following points are taken into consideration before delivery can be effected:
- The site should be level and compacted, it should not slope more than 200mm over the length and 100mm over the width of the unit.
- Site must be accessible for an abnormally large load. All trees and/or other obstacles that may be in the way must be removed beforehand to allow easy access. Gates into property must be a minimum of four (4) metres wide, and truck must have a straight run-up of at least 25 metres to allow bigger units (9m and upwards) to be offloaded into position, and allow trucks to drive out from under unit after having lifting it.
- Unit will be dropped onto trestles and levelled in order to allow doors to open freely. Final levelling must be done by client unless siting is done and charged for by Speedspace.
- A site inspection prior to delivery can be arranged.
| Description | Model | Model | Model | Model | Model | Model | |
|---|---|---|---|---|---|---|---|
| S6241 | 6301 | S96301 | S12301 | S15341 | S18341 | ||
| Length | (ext) | 5750 | 5750 | 9775 | 12075 | 15600 | 18000 |
| (int) | 5670 | 5670 | 9695 | 1995 | 15490 | 17890 | |
| Width | (ext) | 2380 | 2955 | 2955 | 2955 | 3400 | 3400 |
| (int) | 2300 | 2875 | 2875 | 2875 | 3290 | 3290 | |
| Height | (int) | 2400 | 2400 | 2400 | 2400 | 2400 | 2400 |
| Electrics | Std | Std | Std | Std | Std | Std | |
| Aluminium windows | Std | Std | Std | Std | Std | Std | |
| Vinyl floor | Std | Std | Std | Std | Std | Std | |
| Wall insulation | Std | Std | Std | Std | Std | Std | |
| Roof insulation | Std | Std | Std | Std | Std | Std |
Optional Extras
- Exterior skirting
- Carpets
- Burglar bars
- Flyscreens for both windows and doors
- Curtains or blinds
- Air conditioner
- Three-phase electrics
- Geysers (gas or electric)
- Kitchen appliances (gas or electric)
- Carports
- Floor insulation
- Other fittings/applications as per customer request.



